Regions and chambers defined for a fire zone are often not characterized by fire zone use due to misapplication and use of fire-retardant products. Therefore, the use of fire-retardant products will increase the importance of creating fire zones.

Fire retardant products in general;

  • Fire retardant paint
  • Fire resistant mortar
  • Fire stop plate
  • Fire retardant mastic
  • Fire stopper pillow

Fire pipe clamps and fire dampers are used in plastic pipe passages and ventilation passages.

All Sartona Inc and it is implemented by our certified staff.

Fire-stopping Elastic Mastic and Fire-Stopping Mortar products and components must form fire barriers by pressing on the manufacturers of the ventilation ducts in the walls and upholstery passages. To prevent the ventilation channel from bending inwards due to heat, ventilation ducts should be fastened with steel screws to the ventilation channel to be connected with steel screws. Installation of steel screws should be done at a distance of 2 cm from the side of the ventilation duct and then at intervals of 7 cm. In all applications, application thicknesses should be determined based on the approval appropriate to the present situation on the field. According to you, according to the situation on the field, the application should be done in the direction of an authorized and certified person.

Metal pipe passes, mastic and stone solution. Channel usage can be used in some way. Two-sided application must be made in the wall passages, and in the case of slab passages, application in a specified manner.

It is suitable for installation of related products such as ducts for electrical shafts and installation shafts, ducts for cable laying and cable bundles or related products. In all applications, application thicknesses should be determined based on the approval appropriate to the present situation on the field.

kapak-24 FIRE STOPPERS

The building’s most serious fire and dilution based on the risk of smoke spread. Dilatation insulations should be carried out by professional and competent practitioners.

Steel insulation: All steel structures are considered to be anti-fire because there is no fire-spreading danger to the environment and fire-holding flammable materials and steel elements increase temperature above 540 ºC. Single-storey buildings with area less than 5000 m2, other steel structures, steel temperature must be properly segregated. The insulation can be used in the form of spraying with fire-resistant spray plaster, painting with fire-resistant paint, wrapping with fire resistant materials, box taking and massive insulation.